General Information:
DSC mono-conductor multi-function waterflow logging tool consists of pulsed neutron oxygen activation logging tool, neutron lifetime logging tool, natural gamma ray logging tool, casing collar locator and temperature/pressure tool. It can measure parameters such as temperature, pressure, GR, CCL, gamma-ray capture cross section and waterflow in a single logging run.。
Benefits and Features:
- Half-duplex PCM modulation is suitable for either mono-conductor cable or multi-conductor cable.
- A perfect reliability and an easy maintenance with application of computer family, CPLD, DSP and hybrid circuit
- Target voltage stablizing technology of the neutron generator ensures the neutron yield stability and a higher logging precision.
- Neutron sources use a periodic pulse emitting mode to decrease the dissipation of the neutron tube and the neutron generator and ensure their longer operating lifetime.
Specifications:
- Max. Pressure: 80Mpa Max. Temperature: 135℃
- Max. Outer Diameter: 43mm Tool Length : 5500mm
- Natural Gamma Ray Tool:
Measurement range: 0 ~5000cps; permissible measurement error: ±7%
- Pressure Tool
Measurement range: 0~ 80MPa; permissible measurement error: ±I %
- Temperature Tool:
Measurement Range: 0 ~135℃ ; permissible measurement error: ±1℃
- Casing Collar Locator
Measurement range: qualitatively indicate the collar of oil tube/casing.
- Neutron Activation Logging Tool
Measurement range: 6 m3 /d~20 m3/d; permissible measurement error:< ±8%
Measurement range: 20 m3/d~400 m3/d; permissible measurement error:≤±5 %
Measurement range :400 m3/d~600 m3 /d: permissible measurement error:≤±10% - Neutron Lifetime Logging Tool
Measurement range: 7.6c.u.~9lc.u.; permissible measurement error:≤±3 %
Add:Building No. 9, No. 699, Hangtiandonglu, Xi'an, Shaanxi, P.R. China
Tel: 86-29-85930849
Email: aohuaelectronft@163.com